PR260 – 261

Connector for the power supply of pumps, version with locking device that fulfill the requirements of the norm EN 60335-1 about a pull out force value >100 N, suitable for pumps used inside an environment.

Technical Details
Normative references EN 61984
Housing type Free connector, male, non rewirable
Positions 3
Pitch 4,8 mm
Fastening Locking device, press button to unlock
Rated voltage 250 Vac
Rated current, section 0,50 mm2 3A (ambient temperature 75°C)
Rated current, section 0,75 mm2 6A (ambient temperature 45°C)
Frequency 50 / 60 Hz
Rated impulse voltage 2,5 KV (EN 60664-1)
Overvoltage category II (EN 60664-1)
Pollution degree 2 (EN 60664-1)
Degree of protection IP N.A. (to test with the opposite part)
Temperature range LLT -20°C / ULT 90°C
Type of terminals IDC Connections
Connectable conductors Flexible cables
Insulation class I
Test
Glow wire test 850°C / 750°C (EN 60335-1)
Cables
Type H03V2V2-F / H05V2V2-F / UL Style 2103
Section 0,50 mm2 (AWG20)/ 0,75 mm2 (AWG18)
Material Moulding
External insulation PVC TM3 / UL 758 105°C
Internal connector PC-Siloxane
Category
Connectors for pumps and circulators
Certification